FN2030
General Purpose AC/DC EMI Filter with High Attenuation Performance
High Performance Single-Phase Filters FN2030
General Purpose AC/DC EMI Filter with High Attenuation Performance
- Rated currents from 1 to 30 A
- High performance filter attenuation
- High differential-mode attenuation
- Optional medical versions (B type)
- Optional safety versions (A type)
- Optional enhanced performance versions
- Optional overvoltage protection (Z type)
Features and Benefits
1
FN 2030 filters are designed for easy and fast chassis mounting
2
FN 2030 B versions without capacitors to earth comply to 1MOP for ME (medical equipment) acc. IEC 60601-1
3
FN 2030 A versions with low capacitance to earth for safety critical applications with a requirement for low leakage currents
4
FN 2030 filters offer an optimized filter range for high performance AC and DC applications , in same compact size (M, N1 types)
5
All filters provide an exceptional conducted attenuation performance, based on chokes with high permeable core material and excellent thermal behavior
6
The higher inductivity versus amperage offers increased attenuation performance with same form factor compared to FN 2010 and FN 2020 filter series
7
All FN 2030 filters can be delivered with optional surge pulse protection (Z type).
8
Various terminal options allow you to select the desired connection style
Typical Applications
Electrical and electronic equipment
Consumer goods
Household equipment
Medical equipment
Electronic data processing equipment
Office automation and datacom equipment
Various noisy applications requiring high filter performance
Technical Specifications
Rated voltage*
250 VAC, 50/60 Hz
250 VDC
Operating frequency
DC to 400 Hz
Surge pulse protection (Z type)
Helps compliance to IEC61000-4-5 (Differential Mode only)
High potential test voltage
P –> N 1100 VDC for 2 sec
P –> PE 2000 VAC for 2 sec (equiv. cap <88 nF)
P –> PE 2550 VDC for 2 sec (equiv. cap >88 nF)
P –> PE 2500 VAC for 2 sec (B types)
Temperature range (operation and storage)
-25°C to +100°C (25/100/21)**
Certified to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to AC and DC applications)
Flammability corresponding to
Laces for -07 version: UL 94 VW-1
Terminal plastic for -06/-08 version: UL 94 V-0
Grommet for -07 version: UL 94 V-0
Overvoltage category
II acc. IEC 60664-1
Pollution degree
2 acc. IEC 60664-1
Altitude
2000m (above derating applies)**
Rated currents
1 to 30 A @ 40°C max
* maximum RMS operating voltage at rated frequency or the maximum DC operating voltage
** for dedicated requests exceeding this specification (e.g. -40 °C or higher altitude) please contact your local