FN2070
Multi-stage Performance AC/DC EMI Filter
High Performance Single-Phase Filters FN2070

Multi-stage Performance AC/DC EMI Filter
- Rated currents from 1 to 36 A
- High differential and common-mode attenuation
- High frequency attenuation
- Optional medical versions (B type)
- Optional safety versions (A type)
Features and Benefits
1
FN2aFN2070 two-stage filters are designed for easy and fast chassis mounting500 / FN2520 series fits perfectly within 1HU height for rack mount
2
FN2070 B versions without capacitors to earth comply to 1MOP for ME (medical equipment) acc. IEC 60601-1
3
FN2070 A version with low capacitance to earth for safety critical applications with necessity for low leakage currents
4
All filters provide a high conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior
5
FN2070 two-stage filters are designed for high frequency attenuation
6
FN2070 filters are also available as single- stage filters (FN2030 series)
7
FN2070 filters are also available with differential mode choke (FN2080 series)
8
Various terminal options allow you to select the desired connection style
Typical Applications
Electrical and electronic equipment
Consumer goods
Household equipment
Building automation
Industrial applications
Machinery
Medical equipment
Electronic data processing equipment
Office automation and datacom equipment
Various noisy applications requiering good filter performance
Single Phase Motor Drives
Technical Specifications
Rated voltage*
250 VAC, 50/60 Hz
250 VDC
Operating frequency
DC to 400 Hz
Temperature range (operation and storage)
-25°C to +100°C (25/100/21)**
Certified to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to AC and DC applications)
Flammability corresponding to
Laces for -07 version: UL 94 VW-1
Terminal plastic for -06/-08 version: UL 94 V-0
Grommet for -07 version: UL 94V-0
Design corresponding to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Overvoltage category
II acc. IEC 60664-1
Pollution degree
2 acc. IEC 60664-1
Altitude
2000m (above derating applies)**
Rated currents
1 to 36 A @ 40°C max
High potential test voltage
P –> PE 2000 VAC for 2 sec
P –> PE 2500 VAC for 2 sec (B types)
P –> N 1100 VDC for 2 sec
* maximum RMS operating voltage at rated frequency or the maximum DC operating voltage
** for dedicated requests exceeding this specification (e.g. -40 °C or higher altitude) please contact your local